Life is flashing before your eyes Just like butterflies, or the key to paradise Life's out there flashing before your eyes The pace of life will synchronize With the animated energy of surprise Life's right there, in front of your eyes Cherries in a bowl satisfy Your thirst for life will not run dry I said,

Life keeps flashing before your eyes Well, just to philosophize Between two eternities, I realize My life is flashing before my eyes It's just a dream, and my advice Is don't neglect to have a nice Life flash before your eyes Have a nice life flash before your eyesbefore your eyes

Well, just to philosophize Between two eternities, I realize My life is flashing before my eyes It's just a dream, and my advice30.

Garage Door Wont Close Lights Blink 10 Times

Hi, Wayne here from Sears PartsDirect. Todaywe're going to talk about troubleshooting a garage door opener that won't close thedoor and blinks 10 times. The blinking opener lights indicate that the safety sensors arelikely blocked or out of alignment. Defective safety sensors or faulty sensor wiring alsocause the opener lights to blink 10 times. The safety sensors use an invisible beam ofinfrared light to detect obstructions in the garage door's path. The sensors won't allowthe door to close with their infrared beam blocked. First, look for an item blockingthe door and remove it. If there's nothing blocking the safety sensors, check their alignment.You may have bumped a sensor out of position.

Each safety sensor has an indicator light.The sending sensor, which has the yellow light, transmits the infrared beam to the receivingsensor, which has a green light. The yellow sending sensor light should always be lit.But you'll only see the receiving sensor's green light when the sensors are aligned andunobstructed. Make sure that the yellow light is on and then check the green light on thereceiving sensor. If the green light is off, realign the safety sensors until the greenlight turns on then try closing the door. If one or both sensor lights won't come on,check the LED troubleshooting light on the motor unit for an error code. The controlinside the motor unit flashes the troubleshooting

LED a number of times to indicate the causeof a failure. You may see one of these error codes related to the safety sensors on a commonchaindrive garage door opener: 1 blink–Sensor wires are disconnected, 2 blinks–Sensorwires are shorted, 4 blinks–Sensor eyes are slightly misaligned. A beltdrive garagedoor opener and some newer chain drive models flash the up and down arrows to display errorcodes. Here's a list of error codes related to the sensors on these models: Up 1 blink,Down 1 blink–Sensors are not installed or wires are broken, Up 1 blink, Down 2 blinks–Wiresare shorted or reversed, Up 1 blink, Down 4 blinks–Misaligned or obstructed sensor,Up 4 blinks, Down 6 blinks–Sensors were

temporarily obstructed or misaligned. If yousee one of the first two error codes, check the wiring between your motor unit and thesensors for visible damage. You won't be able to check all the wiring if it's routed throughthe walls to the sensors. Check the wires that you can see and repair any broken ordamaged wiring. Here's a tutorial that will give you some additional information about repairingwires. A loose wiring connection could prevent the garage door opener from closing the door,causing an error code. Check the safety sensor wiring connections on the motor unit. Reconnectany loose wires. Make sure that you have the sensor wires connected to the motor unit correctly.You should see the white wires twisted together

and inserted into the white terminal on themotor unit. The white wires with black stripes go into the gray terminal. Connect the wirescorrectly if you find them reversed. If these tips didn't solve your problem, test yoursafety sensors directly at the motor unit. This test will help you determine whetheryou have defective sensors or a break in the wiring that's not visible. We'll check thesending sensor first. Remove the sending safety sensor with the yellow light from its doorrail bracket. Disconnect or cut the sensor wire about 1 foot from the end. The sensorwire has 2 strands. Separate the strands and strip 12inch of insulation from the endof each strand. Disconnect the existing safety

sensor wires from the motor unit. Connectthe short, white wire strand to the white motor unit terminal. Connect the other wirestrand to the gray terminal. Check the yellow light on the sending safety sensor. If theyellow light doesn't turn on, you've confirmed that the safety sensors are defective. Here'sa link to a tutorial that that will show you how to replace them. If the yellow light turnson, then you know that the sending sensor is okay. Now we'll add the receiving sensorto the test. Remove the receiving sensor from its door rail bracket and disconnect or cutthe sensor wire about 1 foot from the sensor end. Separate the sensor wire strands andstrip 12inch of insulation. Disconnect the